Module Tester
Advanced Battery Testing for Module Validation, EOL Inspection, and BMS Verification
The BTS6000 series provides a broader battery testing platform for high-power applications, covering battery module testing, End-of-Line (EOL) inspection, and BMS verification. Designed for EV, energy storage, and other demanding battery applications, the platform supports key testing needs from development to manufacturing, including regenerative charge/discharge testing, safety and performance checks, and communication-based system validation.
- Module Tester — regenerative testing for cycle life, DCIR, pulse, and simulation-based profiles
- EOL Tester — safety and performance checks for production-line validation
- BMS Tester — comprehensive verification of battery management system behavior
Find Your Model
BTS4000
— Compact Low-Voltage Module Testing for R&D and Smart Battery Validation
The BTS4000 module tester is designed for low-voltage battery module testing that requires precise charge/discharge control, fast current response, and dependable data acquisition in a compact 8-channel platform. It is well suited for engineering verification, small battery modules, and smart battery development where stable performance and structured test execution are essential.
- Voltage/current accuracy up to ±0.02% F.S.
- Current response time ≤10 ms
- Supports pulse testing and DCIR
- Kelvin 4-wire data acquisition
- Independent channel control
Applications
LV Module Validation
Smart Battery Development
Engineering Sample Verification
R&D Pilot-line Testing
Tester Model



BTS-4008-20V10A-SR
- Voltage Range: 0.1 V ~ 20 V
- Current Range: 0.05 A ~ 10 A
- Accuracy: ±0.02% F.S.
- Current Response Time: ≤10 ms
- Data Recording Frequency: 10 Hz
- Pulse Width: minimum 100 ms
Datasheet
BTS5000
— High-Precision Module Testing with SMBus Communication Support
The BTS5000 module tester is designed for low-voltage battery module and smart battery pack testing that requires higher precision, flexible current configurations, and SMBus-based communication capability. It supports accurate electrical performance validation across multiple voltage and current ranges, making it suitable for smart battery modules, portable power systems, light mobility applications, and other low-voltage battery systems.
- Voltage/current accuracy: ±0.02% F.S.
- Data recording frequency up to 100 Hz
- Supports SMBus and I2C communication
- Ethernet communication and MES data upload support
Applications
LV Module Validation
Smart Battery Development
Engineering Sample Verification
R&D Pilot-line Testing
Tester Selection



BTS-5008-20V20A-SMB
BTS5000 Module Testser
- Voltage Range: 2.5 V ~ 20 V
- Current Range: 20 mA ~ 20 A
- Power per Channel: 400 W
- Accuracy: ±0.02% F.S.
- Stability: ±0.01% F.S.
- Current Response Time: ≤30 ms
- Data Recording Frequency: 100 Hz
Datasheet



BTS-5008-20V30A-SMB
BTS5000 Module Testser
- Voltage Range: 2.5 V ~ 20 V
- Current Range: 30 mA ~ 30 A
- Power per Channel: 600 W
- Accuracy: ±0.02% F.S.
- Stability: ±0.02% F.S.
- Current Response Time: ≤30 ms
- Data Recording Frequency: 100 Hz
Datasheet



BTS-5008-30V10A-SMB
BTS5000 Module Testser
- Voltage Range: 3 V ~ 30 V
- Current Range: 10 mA ~ 10 A
- Power per Channel: 300 W
- Accuracy: ±0.02% F.S.
- Stability: ±0.02% F.S.
- Current Response Time: ≤20 ms
- Data Recording Frequency: 100 Hz
Datasheet
BTS6000
—Regenerative Battery Module Testing for EV, Energy Storage, and High-Power Applications
The BTS6000 Module Tester is designed for battery module testing that requires wider voltage coverage, higher current capability, and stable dynamic control. It is suitable for battery modules used in electric vehicles, energy storage systems, and high-power battery development.
With configurable voltage ranges from 20 V to 200 V and current options from 30 A to 1200 A, the system supports module-level validation, cycle life testing, DCIR, pulse testing, and simulation-based operating profiles. Its regenerative architecture enables energy recovery during discharge, helping reduce facility power consumption during high-power operation.
- Data recording frequency up to 100 Hz
- Current response time: < 3 ms
- Minimum pulse width: 50 ms
- Regenerative design for energy-efficient testing
- Optional integration with CAN communication, temperature measurement, and auxiliary signals
Applications
EV Battery Module Validation
BESS Module Characterization
Dynamic Load Simulation
R&D and Pilot Line Verification
Tester Selection
Select Voltage → Current → Channels to identify the matching test system configuration



BTS-6000 Standard Specification
- Accuracy: ± 0.02% ~ 0.05%
- Current Response Time: ≤3ms
- Current Conversion Time: ≤6ms
- Data Record Frequency: 100Hz (≤16 channels per station)
- Min. Pulse Width: 50ms
- Input Power Supply: 380Vac 50Hz or 208Vac 60Hz
- Max. System Efficiency (regenerative): 90%
- Communication: Optional CAN & RS485 integration
Please provide the model code to our sales representative for detailed specifications, system configuration, and quotation support.
EOL Battery Testing System
— End-of-Line Testing for Battery Pack Safety, Performance, and BMS Verification
The EOL Battery Testing System is designed for battery pack End-of-Line (EOL) testing, providing a one-stop platform for safety inspection, performance validation, and BMS-integrated verification. It supports production-line testing requirements for power batteries, helping manufacturers complete critical checks before product release.
In addition to standard charge/discharge testing, the system supports insulation resistance, withstand voltage, ACIR/DCIR measurement, and BMS communication-based functional verification. With integrated workflow programming and data traceability capability, it is suitable for battery pack EOL scenarios that require both electrical safety compliance and structured production data management.
- High-voltage safety compliance testing
- Integrated charge/discharge and resistance diagnostics
- BMS communication and functional verification
- Data traceability with barcode and MES integration
Applications
Battery Pack EOL Inspection
Safety Compliance Testing
BMS Functional Verification
Production-Line Validation
Tester Model




CE-6002-200V200A-EOL
- Voltage Range: 12V ~ 200V
- Current Range: 0A ~ 200A
- Accuracy: ±0.02% ~ 0.05% F.S.
- AC Impedance Range: 3mΩ–300Ω
- Withstand Voltage: DC 0.05kV ~ 6kV / AC 0.05kV ~ 5kV
- Multimeter DCV: 100mV ~ 1000V
- Insulation Resistance Simulator: 50Ω ~ 1000MΩ
- I/O Communication: 4× CAN / 4× RS485 / 1× RS232 / 6× Activation Signals