Battery Testing Solutions for Material Research

From coin-cell screening and half-cell evaluation to in-situ analysis and prototype-cell validation, Neware provides battery testing systems, environmental chambers, auxiliary measurement units, and solid-state battery moulds to support the complete material research workflow.

Find the Right Test System

Testing Across the Material Development Process

Coin Cell Testing

Evaluate active material with 2- or 3-electrode coin cells

Half-Cell Evaluation

Assess anode/cathode performance in half-cell configuration

Swagelok Cell Testing

High-pressure cells for advance material screening

Solid-State Cell Research

Test solid-state and modified cells with secure, stable contact

In-Situ and CV Testing

Perform in-situ measurements and CV analysis

Prototype Cell Validation

Validate pouch and cylindrical cells in commercial formats

From Material Screening to Commercial-Form Validation

1
Material
Synthesis
2
Electrode
Fabrication
3
Cell Assembly
(Research Scale)
4
Electrochemical
Evaluation
5
Data Analysis &
Optimization
6
Prototype-Cell
Validation

Recommended Test System for material Research

Test System Selection Guide

Research RequirementRecommended SystemTypical Cell Formats
General material screeningBTS-4008Q-5V100mA-HXW-WCoin cells, Swagelok cells, SSB mould, etc.
In-situ measurement & advanced analysisBTS-8002S-5V100mA-CVCoin cells, single-layer pouch cell, SSB mould, etc.
Prototype-cell validation & scale-upBTS-4008Q-5V6A-S1-WPouch cells, cylindrical cells, etc.

All-In-One Environmental Test Chambers

Neware all-in-one environmental test chambers are designed with dedicated space for integrated battery test systems, reducing the overall equipment footprint and making more efficient use of laboratory space. Internal wiring is pre-arranged for a cleaner and more reliable installation, while on-site setup is greatly simplified. After connecting the system to a computer via Ethernet, installing the software, and completing the IP configuration, the equipment is ready for operation.

WHW-25L-5V100mA
Desktop All-In-One Chamber
  • Temmperature Range: 15~60°C
  • Volume: 25L
  • Inner Dimension:
    W360mm × D300mm × H220mm
  • Outer Dimension:
    W440mm × D550mm × H390mm
  • Fluctuation: ≤ ± 0.5°C
  • Deviation: ≤ ± 2.0°C
  • Integrated Test System: 5V100mA
  • Channel Count: 16 channels
Datasheet
WHW-200L-5V100mA
160CH All-In-One Chamber
  • Temmperature Range: 0~60°C
  • Volume: 200L
  • Inner Dimension:
    W500mm × D500mm × H800mm
  • Outer Dimension:
    W600mm × D920mm × H1800mm
  • Fluctuation: ≤ ± 0.5°C
  • Deviation: ≤ ± 2.0°C
  • Integrated Test System: 5V100mA
  • Channel Count: 160 channels
Datasheet
WHW-200L2-5V100mA
Dual-Zone All-In-One Chamber
  • Temmperature Range: 0~60°C
  • Volume: 100L x 2 zones
  • Inner Dimension (each zone):
    W500mm × D500mm × H400mm
  • Outer Dimension:
    W600mm × D950mm × H1850mm
  • Fluctuation: ≤ ± 0.5°C
  • Deviation: ≤ ± 2.0°C
  • Integrated Test System: 5V100mA
  • Channel Count: 160 channels
Datasheet

+ Auxiliary Measurement Units Add-on

Expand the battery test system with synchronized auxiliary voltage and temperature measurement. These units record external voltage and multi-point temperature data alongside charge–discharge results, helping researchers evaluate thermal behaviour, identify abnormal conditions, and correlate electrochemical performance with temperature changes.

CA-4008n-1U-5VT-TC-DB25
  • Measurement: Voltage / Temperature
  • Voltage Range: 0V–5V
  • Voltage Accuracy: ±0.05% FS
  • Temperature Range: -200°C–260°C
  • Temperature Accuracy: ±1°C
  • Temperature Resolution: 0.1°C
  • Sampling Rate: 10Hz
  • Communication: RS485
  • Protection: Voltage & Temperature Limits
Datasheet
CA-4032n-1U-T-TC-DB25
  • Measurement: Temperature
  • Temperature Range: -200°C–260°C
  • Temperature Accuracy: ±1°C
  • Temperature Resolution: 0.1°C
  • Channels Per Unit: 32 Channels
  • Sampling Rate: 10Hz
  • Communication: RS485
  • Data Export: Excel / TXT
  • Protection: Temperature Upper / Lower Limits
Datasheet

+ Fixtures for Flexible Cell Development

Neware fixtures provide stable electrical contact and secure cell positioning for different stages of battery research and prototype development. Options are available for coin cells, pouch cells, and solid-state battery samples, supporting consistent testing across a wide temperature range and various current or pressure requirements. The modular fixture design also allows researchers to adapt the test setup as cell formats and experimental conditions evolve.

A705-CR-MA-DG
Coin Cell Clamp
  • Contact Resistance: ≤50mΩ
  • Operating Temperature: -40~150℃
  • Battery Thickness: ≤6mm
  • Service Life: >20,000 cycles
A705-P-6A-Mini
Pouch Cell Polymer Clamp
  • Contact Resistance: ≤50mΩ
  • Operating Temperature: -40~150℃
  • Max. Passing Current: 6A
  • Service Life: >20,000 cycles
PCJ-CGS-MJ-TC-5T-D10
Solid-State Battery Mold
  • Sample Size: 10mm
  • Operating Temperature: -40~150℃
  • External Size: Ø 100mm x H150mm
  • Service Life: >10,000 cycles

Not Sure Which Test System Fits Your Research?

The right configuration depends on your cell format, voltage and current range, environmental conditions, contact method, pressure requirements, and research objectives. Share your application details with us, and our engineers will recommend a complete, compatible setup solution.

Configure Your Material Research Test System

Tell us about your research needs and our engineers will recommend the right solution for your application.

Contact Form