Cell Tester
Supporting Electrochemical Cell Testing Across Research and Production
Cell-level battery testers form the foundation of electrochemical performance evaluation, enabling precise control and measurement of individual cells throughout the entire development cycle. From laboratory-scale experimentation to validation and production-oriented testing, Neware cell-level testers are engineered to scale with evolving testing demands.
- High-precision voltage and current measurement suitable for long-duration and repeatability-critical testing
- Flexible compatibility across battery formats, including coin, cylindrical, pouch, and prismatic cells
- Applicability to a wide range of battery chemistries, including lithium-ion, sodium-ion, lithium-sulfur, and emerging systems
Find Your Model
BTS4000
— The Classic Workhorse for Cell R&D
BTS4000 is the most widely adopted platform for routine coin cell and pouch cell testing across material research, cell design validation, and commercial cell verification. It covers common low-to-mid current ranges including 5V/100mA, 6A, 15A, and 30A class configurations, supporting standard charge/discharge, cycling, and performance screening workflows.
BTS4000 is recommended for laboratories requiring cost-effective, scalable testing throughput for mainstream cell characterization, where portable operation or ultra-fast transient measurement is not required.
Applications
Material Evaluation
Cell Design Verification
Process Validation
Cycle-life Testing
Tester Selection





BTS-4008Q-5V100mA
- Max. Voltage: 5V
- Min. Discharge Voltage: -5V
- Auto-Switch Ranges: 0.1mA/1mA/10mA/100mA
- Accuracy: ± 0.02%
- Channels Per Unit: 8 Channels
- Data Record Frequency: 10Hz
- Min. Pulse Width: 500ms





BTS-4008Q-5V6A
- Max. Voltage: 5V
- Min. Discharge Voltage: 1.5V
- Auto-Switch Ranges: 100mA/500mA/3A/6A
- Accuracy: ± 0.02%
- Channels Per Unit: 8 Channels
- Data Record Frequency: 10Hz
- Min. Pulse Width: 500ms





BTS-4008Q-5V15A
- Max. Voltage: 5V
- Min. Discharge Voltage: 2.0V
- Auto-Switch Ranges: 300mA/3A/6A/15A
- Accuracy: ± 0.02%
- Channels Per Unit: 8 Channels
- Data Record Frequency: 10Hz
- Min. Pulse Width: 100ms




BTS-4008Q-5V30A
- Max. Voltage: 5V
- Min. Discharge Voltage: 1.5V
- Auto-Switch Ranges: 1A/6A/12A/30A
- Accuracy: ± 0.02%
- Channels Per Unit: 8 Channels
- Data Record Frequency: 10Hz
- Min. Pulse Width: 100ms
BTS8000
— Portable Testing for In-situ & On-site Scenarios
BTS8000 is designed for test scenarios where the measurement system must be deployed directly at the experiment location. It supports portable operation via a Type-C power interface, allowing use with approved external power sources (such as portable power banks), subject to system configuration and site-specific safety requirements.
In addition to standard charge and discharge functions, BTS8000 supports advanced electrochemical test methods, making it suitable for both laboratory and field-adjacent environments. Its enhanced data acquisition capability enables detailed performance monitoring during dynamic or in-situ test conditions
Applications
Cyclic Voltammetry (CV) Testing
In-situ Battery Experiments
On-site or Shared-lab Testing
Rapid Diagnostic Checks
BTS9000
— Premium High-Speed Acquisition & Pulse Characterization
BTS9000 is designed for advanced cell characterization applications where high sampling frequency, fast transient response, and precise control are required. It is particularly suited for consumer electronics and other applications involving dynamic load conditions, short-duration pulses, and high-resolution performance analysis.
- Data acquisition frequency up to 1000 Hz
- Minimum pulse width of 400 μs for rapid pulse testing
- Accuracy reference of 0.02% F.S.
- Optimized for high-resolution profiling of dynamic load and pulse response behavior
Applications
SMB Communication
Commercial Electronics
Fast Pulse Test
High-resolution Profiling
Tester Selection




BTS-9004-5V5A
BTS9000 Cell Testser
- Max. Voltage: 5V
- Min. Discharge Voltage: 0.7V
- Auto-Switch Ranges:
150μA/5mA/150mA/5A - Accuracy: ± 0.02%
- Channels Per Unit: 4 Channels
- Data Record Frequency: 1000Hz
- Min. Pulse Width: 400μs
Datasheet





BTS-9008-5V5A
BTS9000 Cell Testser
- Max. Voltage: 5V
- Min. Discharge Voltage: 0.7V
- Auto-Switch Ranges:
150μA/5mA/150mA/5A - Accuracy: ± 0.02%
- Channels Per Unit: 8 Channels
- Data Record Frequency: 1000Hz
- Min. step time: 10ms
Datasheet





BTS-9008-5V15A
BTS9000 Cell Testser
- Max. Voltage: 5V
- Min. Discharge Voltage: 2.85V
- Auto-Switch Ranges:
15mA/150mA/1.5A/15A - Accuracy: ± 0.02%
- Channels Per Unit: 8 Channels
- Data Record Frequency: 1000Hz
- Min. step time: 10ms
Datasheet
BTS6000
— High-Current Regenerative Testing for EV and Energy Storage Applications
BTS6000 is designed for high-current cell testing requiring elevated load capability, dynamic control, and energy-efficient operation. The series covers current configurations from 50 A to 2000 A, making it suitable for large-format pouch (including blade-type) and prismatic cells used in electric vehicle (EV) and energy storage applications. The system features a regenerative architecture, enabling energy recovery during discharge and supporting reduced power consumption during high-current operation.
- Data recording frequency up to 100 Hz
- Current response time: < 3 ms
- Minimum pulse width: 50 ms
- Support for programmable and simulation-based test profiles
Applications
EV Traction Cell Validation
High C-rate Testing
Dynamic Load Simulation
BESS Cell Characterization
Tester Selection
Select Voltage → Current → Channels to identify the matching test system configuration



BTS-6000 Standard Specification
- Max. Voltage: 5V/6V
- Min. Discharge Voltage: 1.5V (upgrade version to -5V)
- Accuracy: ± 0.02% ~ 0.05%
- Current Response Time: ≤3ms
- Current Conversion Time: ≤6ms
- Data Record Frequency: 100Hz (≤16 channels per station)
- Min. Pulse Width: 50ms
- Input Power Supply: 380Vac 50Hz or 208Vac 60Hz
- Max. System Efficiency (regenerative): 75%